Read the blog to see how expanded corrosion modeling improves prediction accuracy and supports more reliable asset integrity decisions.
Corrosion Risk. Quantified.
Corrosion in upstream production systems are governed by fluid chemistry, material exposure, and operating conditions. OLI calculates corrosion rates using thermodynamics to define the chemistry, quantify the speciation of key corrosion drivers, and combine these results with a best-in-class electrochemical model.
Foundations of Corrosion Prediction
Material degradation in oil and gas production is driven by CO₂, H₂S, O₂, organic acids, and evolving water chemistry. Accurate corrosion prediction requires reliable pH, gas partitioning, and salinity. OLI provides the thermodynamic chemistry foundation needed to couple these factors with advanced electrochemical models for accurate corrosion rate prediction.
Trusted for Integrity Decisions
Applied by engineering teams evaluating carbon steel performance, CRA material selection, and corrosion mitigation strategy under defined operating envelopes.
Corrosion Risk and Operating Limits Defined by Fluid Chemistry
Quantitative corrosion modeling links material selection to real fluid conditions, defining safe operating envelopes and supporting inspection and mitigation decisions.
Material Selection
Determine whether carbon steel or corrosion-resistant alloys are appropriate under predicted CO₂, H₂S, and O₂ exposure.
Operating Window Definition
Evaluate how temperature, pressure, and water composition influence corrosion rate and define acceptable limits.
Risk Quantification
Calculate corrosion rates under multiphase conditions to support inspection planning and mitigation strategy.
Corrosion prediction begins with correct speciation. If pH and acid gas partitioning are approximated, predicted rates will not reflect field behavior.
Diana Miller
Principal Client Solutions Architect
Corrosion Modeling in Upstream Systems
Technical guidance on how OLI calculates corrosion rates, evaluates sour conditions, and links material selection to consistent stream chemistry across the production profile.
OLI identifies corrosion drivers through thermodynamic speciation, predicting pH and the concentration of dissolved acid gases such as CO₂ and H₂S. These chemistry results are integrated into mechanistic corrosion models to estimate carbon steel corrosion rates under defined operating conditions. Corrosion predictions are available for carbon steel and more than 20 corrosion-resistant alloys (CRAs) to support reliable material selection.
Yes. OLI has extensively studied the influence of H₂S on corrosion rates. The analysis begins by characterizing the fluid chemistry and speciation and how these evolve with temperature, pressure, and salinity. The corrosion kinetics model then accounts for the potential formation of FeS films and predicts corrosion rates under defined conditions. This supports the evaluation of sour corrosion risk in production systems.
Yes. Predicted fluid chemistry, along with general and localized corrosion predictions, is used to compare expected material performance under defined exposure conditions. This provides a defensible basis for evaluating material suitability and screening the most appropriate materials.
OLI incorporates the impact of oxygen on both general and localized corrosion rates. Oxygen concentration is specified as an input in the stream model, and the resulting dissolved oxygen is included in the corrosion rate calculations.
Yes. Fluid chemistry can be re-calculated at successive pressure conditions from reservoir to surface, allowing corrosion risk to be assessed across the production profile.
Corrosion models rely on consistent stream definitions. A validated fluid model can be used directly in corrosion and scaling calculations to maintain chemical consistency across analyses.
Expanding corrosion prediction with the MSE model
Corrosion prediction becomes more complex as operating environments move beyond traditional water-based systems. Many upstream conditions involve mixed solvents, CO₂-rich fluids, and elevated temperatures, where standard approaches rely on assumptions and limited data. The expanded MSE corrosion model extends predictive capability across a broader range of materials and conditions, including alloys used in demanding environments. This allows engineers to assess corrosion risk more accurately, understand material performance under real conditions, and reduce uncertainty in design and operation.
Predict Corrosion Rates. Protect Asset Integrity.
Corrosion risk in upstream systems depends on fluid chemistry, phase behavior, and material exposure. OLI defines the chemistry through thermodynamics and applies electrochemical models to calculate corrosion rates under real operating conditions. Evaluate the impact of CO₂, H₂S, O₂, and water chemistry as pressure and temperature change. Link material selection to quantified corrosion behavior and define safe operating limits. Share your corrosion challenges to assess risk, guide mitigation, and support long-term asset performance.